You are reviewing a fleet report or a dealer dashboard and see two percentages for the same pack: one near 80% and another near 70%. Before you schedule a mower, quote a replacement, or reassure a customer, you need to know which number answers which question. This guide to battery state of charge vs state of health explains what each indicator represents, why two readings can disagree, and what a dealer or fleet lead should confirm before acting.
State of charge (SOC) estimates how much usable charge remains now, relative to a stated capacity basis. State of health (SOH) estimates the pack's present condition relative to an initial reference. They answer different questions, use different references, and can legitimately differ for the same battery.
The distinction matters most in fleet work, where a single percentage is often copied into a spreadsheet and treated as a verdict. The sections below cover what each indicator means, why two packs or two readings can disagree, and what to confirm before you act on either number.
Battery state of charge vs state of health: Separate present charge from the health baseline

SOC and SOH are both estimates, not direct physical quantities you can read off a cell like a temperature. Analog Devices describes SOC and SOH estimation techniques as separate problems, and Epic Power's definitions document treats state of charge, state of health, and state of power as distinct concepts. That framing is the practical starting point: a display may show both, but each is produced from its own inputs and its own reference.
Explain SOC as available charge relative to a stated capacity basis
SOC describes the charge currently available as a proportion of some capacity figure. The critical phrase is "stated capacity basis." That basis might be a nominal rated capacity, a measured capacity at a defined condition, or a value the battery management system (BMS) has learned over time. Two systems can report different SOC for the same pack if they divide remaining charge by different denominators.
For a dealer or fleet lead, the practical question is not only "what percentage is shown?" but "percentage of what?" A reading taken at rest, a reading taken under load, and a reading taken shortly after charging can differ because the underlying measurement conditions differ. Analog Devices' discussion of estimation techniques makes clear that SOC estimation is an inference problem with method-dependent behavior, not a single universal formula.
This is also why SOC alone cannot tell you how long a mower will run. A pack at 60% SOC on a healthy battery and a pack at 60% SOC on a degraded battery can hold very different amounts of actual energy. The percentage is a ratio, and the denominator may have changed. For the capacity concepts behind that denominator, see the Super Mowers explanation of battery amp hours.
Explain SOH as a condition estimate relative to an initial reference
SOH describes present condition relative to a reference state, typically the pack's condition when new or when first characterized. It is a comparison across time, not a snapshot of remaining charge. Epic Power's definitions document frames state of health in relation to a reference, which is exactly why SOH figures are not automatically comparable between products: the reference and the measured quantity can differ.
SOH may be expressed through capacity retention, internal resistance growth, or a composite score, depending on the system. A BMS that reports "SOH 85%" may mean the pack now delivers 85% of an initial capacity figure, or it may mean something else defined by that manufacturer's algorithm. Without the definition, the number is a label, not a specification.
Hella's Intelligent Battery Sensor (IBS) documentation is a useful illustration of how sensor-based battery monitoring is described for the battery types it lists, such as starter, EFB, gel, and AGM batteries. It is an example of a named sensor product in its own stated context. It is not evidence that a lithium mower pack, or any Super Mowers model, includes that sensor or reports SOH in the same way.
Compare illustrative indicator values without predicting runtime

A common fleet scenario is a pack that reads high on charge and lower on health. That combination is not a contradiction; it is two different estimates answering two different questions. The table below is an illustrative comparison of indicator patterns, not measured data from any specific product.
| Indicator pattern | What it suggests | What it does not establish |
|---|---|---|
| High SOC, high SOH | Pack is well charged and its condition estimate is close to its reference | Actual runtime, safety, or suitability for a specific task |
| High SOC, lower SOH | Pack is charged now, but its condition estimate has moved from the reference | Remaining useful life in hours, or a replacement date |
| Lower SOC, high SOH | Pack is partly discharged but its condition estimate remains near reference | That the pack will accept a full charge or deliver rated capacity |
| Lower SOC, lower SOH | Both estimates have moved | The cause of degradation, or whether the pack is safe to use |
Show why one pack can have different SOC and SOH percentages
The simplest reason is that the two percentages have different denominators and different time horizons. SOC is anchored to a capacity basis and moves within a charge cycle. SOH is anchored to an initial reference and moves over the pack's life. A pack can be at 90% SOC while its SOH estimate sits at 75%, because the first number describes today's charge and the second describes how far the pack has drifted from its reference condition.
A second reason is method. Different estimation approaches can produce different values from the same physical pack. Analog Devices' overview of SOC and SOH estimation techniques shows that these are modeling problems with different inputs and assumptions. When a dealer compares a reading from a mower display with a reading from an external tester, disagreement does not automatically mean one device is faulty.
A third reason is condition. Temperature, load history, rest time before measurement, and the point in the charge or discharge cycle can all affect estimates. A percentage captured immediately after a hard mowing session is not the same measurement as one captured after the pack has rested.
Discuss the effect of methods and conditions on estimates
Estimation method shapes what the number means. A coulomb-counting approach tracks charge in and out and depends on a capacity reference; a voltage-based approach infers charge from cell voltage and is sensitive to load and rest; model-based approaches combine signals. Analog Devices' article treats these as distinct techniques with their own assumptions, which is the right level of caution for a fleet lead reading a dashboard.
Conditions matter just as much. A pack measured cold, hot, under load, or immediately after charging may report differently from one measured at rest in a stable environment. The useful discipline is to record the conditions alongside the number: when it was read, what the equipment was doing, and which device produced it. Without that context, two percentages from two days can look like a trend when they are only a difference in measurement conditions.
Use indicators in equipment fleet decisions

For dealers and fleet leads, SOC and SOH are decision inputs, not decision outputs. They help you ask better questions about charging schedules, rotation, warranty conversations, and replacement planning. They do not, on their own, certify a pack for a task or prove that a pack is safe.
Ask which sensor, algorithm and reference the display uses
The first question for any indicator is provenance. Who produced the number, from what inputs, against what reference? A BMS, an external tester, a charger, and a dealer's spreadsheet may all report "SOC" while meaning different things. The same applies to SOH.
The table below is a practical checklist for dealer and fleet conversations. It separates what you can confirm from what remains an open question.
Application review
Discuss your mowing application.
Share the working condition, target market, product family and project scope.
| Question to confirm | Why it matters | Status if unanswered |
|---|---|---|
| Which device produced the SOC reading? | Different devices use different methods and references | Treat the value as device-specific, not universal |
| What capacity basis does SOC use? | A changed denominator changes the percentage | Do not compare SOC across products without confirming the basis |
| How is SOH defined by this supplier? | Capacity retention, resistance, or composite scores are not interchangeable | Do not compare SOH figures across brands |
| What was the initial reference? | SOH is meaningless without knowing the baseline | Ask for the reference condition and date |
| Under what conditions was the reading taken? | Load, temperature, and rest time affect estimates | Record conditions with every reading |
| Does the display or BMS expose these values at all? | Some equipment may not report SOC or SOH in the form you expect | Confirm from the model's documentation, not from assumption |
For Super Mowers specifically, the public product page for the DY-550E lithium electric mower is a starting point for model background, but it should not be read as confirmation that the model's BMS displays SOC or SOH, or that any particular algorithm is used. Those details require model-specific documentation. Dealers should ask the supplier directly rather than inferring features from a category page.
Do not infer safety or a model feature from a percentage
A percentage is not a safety certificate. A high SOC does not prove a pack is safe, and a low SOH does not by itself prove a pack is unsafe. Safety judgments belong to the applicable documentation, the manufacturer's instructions, and the responsible organization's procedures, not to a dashboard value.
Similarly, a percentage does not prove a feature exists. Seeing "SOC" in a brochure does not confirm how it is calculated, and seeing "SOH" in a competitor's material does not mean a Super Mowers model offers the same function. Feature claims should be confirmed against the specific model's documentation.
For related background, see the Super Mowers explanations of battery amp hours and lawn mower battery cycle life. Those articles cover capacity and cycle-life concepts; this one focuses on why SOC and SOH are separate estimates.
FAQ

Can a battery show high charge and reduced health?
Yes. SOC and SOH use different references. A pack can be well charged today while its condition estimate has moved from its initial reference. The two values describe different things and are not required to match.
Does SOH use the same definition in every product?
No. SOH is a condition estimate relative to a reference, and the measured quantity and reference can differ between suppliers and systems. Epic Power's definitions document treats state of health as a distinct concept, and Analog Devices' overview shows estimation methods vary. Compare SOH only when the definition and reference are known.
Can one indicator prove a battery is safe?
No. A single percentage does not establish safety. Safety judgments should rest on the applicable manufacturer documentation, instructions, and the responsible organization's procedures, not on a displayed SOC or SOH value.
Conclusion

SOC describes charge now; SOH describes condition against a reference. Confirm the device, method, and reference before comparing values across packs or brands, and never treat a percentage as proof of safety or a feature.
Sources and further reading
- A Closer Look at State of Charge (SOC) and State of Health (SOH) Estimation Techniques for Batteries — Analog Devices
- Hella Intelligent Battery Sensor (IBS) 24V FORVIA documentation
- State of Charge, Health and Power in batteries — Definitions (Epic Power)
Video: State of Health of battery | Battery SOH | Battery Management System


