A dealer's spare-parts desk receives a request for "the pressure valve" on a mower's hydraulic lift circuit. The parts list shows two different Danfoss designations, and the customer wants to know whether they can be swapped. They cannot be treated that way without checking the circuit and the exact model data.
In any hydraulic equipment relief valve vs pressure reducing valve comparison, the first difference is the control task: a relief valve limits pressure in a circuit, usually by sending excess flow to tank. A pressure-reducing valve controls pressure downstream in a branch, and some designs, including the Danfoss PRV1-10, also relieve downstream pressure back to tank under certain conditions. Similar names do not make the two interchangeable.
The rest of this article separates the two control tasks, shows how to read named manufacturer data, and sets out what to record before asking a supplier about a specific valve.
Hydraulic equipment relief valve vs pressure reducing valve: Separate circuit pressure protection from branch control

The first question is not "which valve is better?" It is "what is this valve doing in this circuit?" A relief valve and a pressure-reducing valve sit in different positions and answer different questions. One protects a circuit or a component from excessive pressure; the other holds a branch at a lower pressure than the supply. Confusing the two leads to wrong part requests, wrong settings assumptions, and parts that physically fit but do not perform the intended job.
Identify upstream and downstream roles
In the simplest description, a relief valve is an upstream pressure-limiting device. It is arranged so that when pressure reaches its setting, flow is allowed to pass to tank, which caps the pressure the circuit can develop. That is a protection and limiting function. The exact arrangement, porting, and internal design depend on the valve and the circuit, so the description is a starting point for identification, not a universal installation rule.
A pressure-reducing valve works on the downstream side. It takes a higher supply pressure and holds a lower pressure in the branch it serves. The Danfoss PRV1-10 is described as a direct-acting pressure-reducing and relieving valve. That "relieving" part matters: the same component can reduce pressure downstream and, under the conditions described in the manufacturer's data, relieve downstream pressure back to the return line. A parts reader who sees "reducing" in the name and assumes the valve has no relieving behavior may misread the circuit.
The practical consequence is that the two valves are not two versions of one part. They are answers to two different control questions. A relief valve is asked "how high may this circuit pressure go?" A reducing valve is asked "how low should this branch be held, and what happens if something pushes pressure back into it?"
Confirm exact circuit and installed devices
Before comparing catalogue entries, confirm what is actually fitted. The machine identity, the circuit being discussed, and the valve designation on the component or in the parts documentation should all be recorded. A name on a schematic, a similar-looking body, or a remembered part number is not enough to establish that a specific valve is installed.
For a mower with a hydraulic lift, the lift circuit may contain several pressure-related components, and the presence of one does not prove the presence of another. Super Mowers' Remote 50 product page lists hydraulic lifting as a feature. That listing does not establish which pressure-control valves are fitted, how they are set, or whether a reducing valve is used anywhere in the machine. Treat the product page as a machine-level description, not as a valve specification.
A useful first pass is to write down what is known and what is not:
| Question | Why it matters | Status to record |
|---|---|---|
| Which machine and serial number? | Ties the enquiry to the correct build and documentation | Confirm from plate or records |
| Which circuit is affected (lift, steering, auxiliary)? | Different circuits can use different pressure-control arrangements | Confirm from machine documentation |
| What valve designation is fitted? | Prevents substitution based on appearance | Confirm from the component or parts list |
| Is the valve limiting circuit pressure or holding a branch lower? | Determines which product family to look at | Confirm from the schematic or a qualified technician |
| What documents are available (manual, schematic, parts list)? | Lets the supplier check the exact configuration | List what you can send |
If the circuit role cannot be established from available documents, that is the finding to report. It is not a reason to guess.
Read named manufacturer product data

Named manufacturer data is more useful than generic descriptions because it shows how a specific product family is presented, what its ratings mean, and where the limits of a catalogue entry lie. The Danfoss catalogue material on the PRV1-10 reducing valve and the related RV1-10 relief valve material cover direct-acting valves in these two families. Reading those entries side by side shows both the difference in function and the care needed before treating any two designations as alternatives.
Read Danfoss PRV1-10 reducing valve designation
The PRV1-10 is presented as a direct-acting pressure-reducing valve with a relieving function. In the catalogue structure, the reducing valve appears under its own designation, and the relieving behavior is part of how the product is described rather than an add-on. That is the detail that makes a simple "reducing valves do not relieve" statement inaccurate for this product family.
Reading the designation properly means reading more than the family name. The catalogue entry carries the information needed to identify the product: its function, its rated pressure information, its flow-related data, and the way its adjustment is described. Those items belong together. A part number copied without the surrounding data can identify a family but not confirm that a particular unit matches a particular circuit.
For a dealer or spare-parts desk, the practical reading habit is to keep the manufacturer's designation, the catalogue section, and the document revision together in the enquiry record. If a customer later asks why a certain valve was quoted, the record shows which catalogue entry the quote was based on.
Find a documented relief valve to compare
A fair comparison needs a documented relief valve, not a general impression of what relief valves do. The Danfoss RV1-10 direct-acting relief valve, listed in the related catalogue material, provides that comparison point. It is a distinct product family with its own designation and its own data. The comparison is between two named catalogue entries, not between a real valve and a remembered category.
That distinction protects the reader from a common error. Many general articles describe relief and reducing valves in broad functional terms, and the broad terms are often correct. But when the task is to identify a replacement part, the broad description does not decide which catalogue entry applies. The named entries do. The RV1-10 and PRV1-10 should be compared on their documented functions and data, and neither should be assumed to substitute for the other because the designations look similar.
A second limit applies to the comparison itself. The catalogue material describes product families and their presentation. It does not establish what is fitted to any particular mower, including a Super Mowers machine. The comparison is useful for understanding the two control tasks and for framing an enquiry; it is not a machine-specific installation record.
Separate rated limits, settings and flow conditions

Application review
Discuss your mowing application.
Share the working condition, target market, product family and project scope.
Catalogue values are easy to misread because they sit close together on a page. A rated pressure, a pressure setting, and a flow condition are three different things, and mixing them produces confident but wrong conclusions. The safe habit is to read each value with its label, its unit, and its stated condition, and to keep the values attached to the exact product and document they came from.
Do not treat rating as actual system setting
A rated pressure in a catalogue is a product limit or a declared characteristic of the valve family. It is not a statement that the valve on a given machine is set to that pressure. The installed setting is a property of the specific unit and its adjustment, and it should be confirmed from the machine's documentation or by qualified service personnel, not inferred from a catalogue maximum.
This matters for spare-parts work because a customer may ask for "the valve set at the catalogue pressure." The honest answer is that the catalogue entry describes the product, while the machine's setting is a separate question. If the setting is not documented, the gap should be recorded as a gap. Supplying a valve on the assumption that its factory condition equals the machine's required setting is a guess dressed as a specification.
The same caution applies to flow. A valve's flow-related data is stated under particular conditions in the manufacturer's material. It is not a promise about what the valve will do in a different circuit with different flow, different fluid conditions, or a different adjustment. Reading the condition along with the number is part of reading the number.
Keep model-specific values in context
A practical comparison table for an enquiry should separate what the manufacturer states from what the machine requires. The table below is a structure for recording that separation; the entries are the questions to answer, not invented values.
| Data item | What the manufacturer document provides | What the machine record must provide |
|---|---|---|
| Function | The product family's stated control task | Which task the circuit needs |
| Rated pressure | The declared product rating, with its stated basis | The pressure the circuit is designed for |
| Setting | How adjustment is described in the catalogue | The installed setting, if documented |
| Flow data | Flow-related information under stated conditions | The flow the circuit actually sees |
| Designation | The exact catalogue designation | The designation fitted or specified |
| Document revision | The catalogue document and revision | The manual or parts list revision used |
Filling this table honestly often reveals that the enquiry is not yet ready. That is a useful outcome. A supplier who receives a designation plus the machine identity plus the available documents can check compatibility against the right source. A supplier who receives only a description of the symptom has to guess.
Prepare a model-specific supplier enquiry

A good valve enquiry is short but complete. It identifies the machine, the circuit, the fitted or specified valve, and the documents available. It states what is known and what is not. It does not ask the supplier to confirm a setting that only the machine's documentation or qualified service can establish.
Record machine identity and available documents
Start with the machine. The model, serial number where available, and the circuit in question give the supplier the context needed to check the correct documentation. Then list the documents on hand: operator's manual, parts list, schematic, previous service records, and any valve designation visible on the component. Note the revision or date of each document where it is shown.
Next, describe the observed situation without diagnosing it. "The lift circuit is not holding pressure" is an observation. "The relief valve is worn out" is a diagnosis. The first invites a documented check; the second pushes the supplier toward a part before the circuit role is confirmed. For related background on how flow and pressure behave in a hydraulic circuit, the site's article on hydraulic flow versus pressure and cylinder speed and force provides useful context for the conversation.
Finally, state the question plainly. Is the request to identify the valve family, to confirm a designation against a parts list, or to source a replacement for a recorded part number? Each question needs different evidence, and separating them keeps the enquiry accurate.
Leave adjustment and testing to qualified service
Pressure settings and valve adjustment are not parts-desk tasks. The catalogue may describe how a valve is adjusted, but that description is not an instruction to adjust a machine's hydraulic system. Setting, testing, and any work on a pressurized circuit belong with qualified service personnel using the machine's own documentation and appropriate equipment.
This boundary protects the dealer as much as the customer. A parts recommendation based on a catalogue entry is a sourcing answer. A pressure setting is a service decision. Keeping the two separate means the dealer can supply the right family and designation while the service side confirms the installed configuration and setting.
A short enquiry checklist helps keep that separation visible:
| Enquiry element | Include it? | Note |
|---|---|---|
| Machine model and serial number | Yes | From the plate or records |
| Circuit affected | Yes | Lift, steering, or auxiliary |
| Fitted valve designation | If known | From the component or parts list |
| Documents available | Yes | List manual, parts list, schematic, revisions |
| Observed symptom | Yes | Describe, do not diagnose |
| Requested action | Yes | Identify, confirm, or source |
| Installed pressure setting | Only if documented | Otherwise mark as unknown |
| Adjustment request | No | Refer to qualified service |
FAQ

Does every mower hydraulic circuit use both valves?
No. The presence of a relief valve does not establish that a reducing valve is also fitted, and the reverse is also true. The valves serve different control tasks, and a given circuit may use one, both, or neither depending on its design. The only reliable answer comes from the machine's own documentation and the components actually fitted. A product page that lists a hydraulic feature, such as the Remote 50's hydraulic lifting, does not by itself identify the pressure-control valves in the circuit.
Does a catalogue maximum equal the installed pressure setting?
No. A catalogue rating describes the product family and its declared characteristics. The installed setting is a property of the specific unit and its adjustment on the machine. Treating a catalogue maximum as the machine's setting is an assumption, not a reading. If the setting is not documented, record it as unknown and let qualified service confirm it.
Conclusion

Relief and reducing valves answer different pressure-control questions, and named catalogue entries such as the Danfoss RV1-10 and PRV1-10 should be read on their own terms. Record the machine, circuit, and documents before asking a supplier to confirm a part.
Video: Difference between Pressure relief valve & Pressure reducing valve